Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/12/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Re-inspection required | Inspection canceled by contractor 4/10/24 need R-8 insulation per IRC and BOCA plates on dryer vent top plates 4/12/24: R-8 insulation required per IRC, BOCA plates on dryer vent top plate, blocking at registers, seal all penetrations going through vapor barrier, seal all penetrations going through top plate. |
|
| 04/18/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | This intermediate inspection is for the guest house. HVAC system is complete and approved. |