Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Parcel: 123140130


Addresses:

948 E WAVERLY ST


Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Permit Number - TC-RES-0923-07897

Inspection Description - COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
06/27/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required 6-27-25: missing anchor bolts throughout-see wb schedule for details. Missing bathroom reinforcement/backing see inclusive notes, wb1-calls for 6" o.c. Along edges and 12" o.c. In the field-add nails according to schedule. Some of sheathing marked but have framer walk it over. Provide ladder for roof inspection and truss calcs.
07/08/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed