Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
Permit Number - TC-RES-0923-07897
Inspection Description - COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
Inspection Status - Re-inspection required
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/27/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | 6-27-25: missing anchor bolts throughout-see wb schedule for details. Missing bathroom reinforcement/backing see inclusive notes, wb1-calls for 6" o.c. Along edges and 12" o.c. In the field-add nails according to schedule. Some of sheathing marked but have framer walk it over. Provide ladder for roof inspection and truss calcs. | |
| 07/08/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed |