Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: TC-RES-0826-04731

Parcel: 129020630

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Roof NailingĀ 

Date Description Inspector Results Comments
10/26/2026 COT - RSBU - Roof NailingĀ  Re-inspection required Provide blocking to seam to ensure 6" are nailed at all perimeters. Re inspect nailing pattern at sheathing edges. 6" o.c. Provide nails at ledger north end. Provide cs16 strap from header to post at first entry west wall. Loos roof sheathing ensure 6/12 nailing pattern is in place. 10/26/2026
10/28/2026 COT - RSBU - Roof NailingĀ  Passed 10/28/2026
All corrections made.