Permit: TC-RES-0826-04425

Parcel: 134042200


Addresses:

8919 E KENYON DR

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.

Date Description Inspector Results Comments
09/08/2026 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Re-inspection required 1. Kitchen countertop receptacles will require proper spacing per 2023 NEC, all kitchen receptacles will need to be on a GFCI to include the Range.
2. For your building final, you will need a carbon monoxide detector in the immediate vicinity of all the bedrooms.
3. Each vanity in the bathroom will require a GFCI receptacle
4. Copper pipe in hallway bathroom was spraying water due to a score in the pipe done with a pipe cutter; please dry or replace any damaged materials prior to next inspection.
5. At final, Water hammer arrestors will be needed at dishwasher, ice makers, and washers.
09/21/2026 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed Passed