Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: TC-RES-0826-04384

Parcel: 141143920


Addresses:

9525 E LOCHNAY LN

Inspection Status: Re-inspection required

Inspection History: COT - RSPL - Plumbing Final 

Date Description Inspector Results Comments
08/14/2026 COT - RSPL - Plumbing Final  Re-inspection required 8-14-26: missing hammer arrestor at dishwasher line, add insulation to copper line at hose bib, add insulation to hot water line at water heater, fire foam penetrations at 2nd floor decking located at spare bedroom/bathroom, & master bedroom closet, add insulation above ceiling to hot pex lines throughout.
08/20/2026 COT - RSPL - Plumbing Final  Re-inspection required 8-20-26 add insulation to all pex/copper lines throughout unconditioned spaces (garage area)