Inspection Status: Re-inspection required
Inspection History: COT - RSPL - Plumbing Final
| Date |
Description |
Inspector |
Results |
Comments |
| 08/14/2026 |
COT - RSPL - Plumbing Final |
|
Re-inspection required |
8-14-26: missing hammer arrestor at dishwasher line, add insulation to copper line at hose bib, add insulation to hot water line at water heater, fire foam penetrations at 2nd floor decking located at spare bedroom/bathroom, & master bedroom closet, add insulation above ceiling to hot pex lines throughout. |
| 08/20/2026 |
COT - RSPL - Plumbing Final |
|
Re-inspection required |
8-20-26 add insulation to all pex/copper lines throughout unconditioned spaces (garage area) |
| 08/24/2026 |
COT - RSPL - Plumbing Final |
|
Passed |
8-24-26 All items have been corrected. OK to proceed |