Inspection Status: Not Ready
Inspection History: COT - RSPL - Plumbing Final
| Date |
Description |
Inspector |
Results |
Comments |
| 08/18/2026 |
COT - RSPL - Plumbing Final |
|
Not Ready |
Provide WR receptacles at outdoor locations. Provide receptacle within 2’ from kitchen sink. Provide hammer arrestor at hot line for dishwasher. Missing receptacle at counter top near refrigerator. Caulk toilets. Provide receptacle at hallway. PRV shall be solid. Check off labeling at air handler. Coat exterior pipes on roof. Provide proper support at condensation line east unit. 8/18/2026 |
| 08/21/2026 |
COT - RSPL - Plumbing Final |
|
Passed |
Corrections made |