Permit: TC-RES-0825-03974

Parcel: 136202440


Addresses:

2602 S CAMINO SECO

Inspection Status: Passed

Inspection History: RSPL - Plumbing Progress

Date Description Inspector Results Comments
08/24/2026 RSPL - Plumbing Progress Passed
11/04/2025 RSPL - Plumbing Progress Not Ready Not ready; remove insulation to allow for framing/intermediate inspections.
11/10/2025 RSPL - Plumbing Progress Not Ready 1-Studor vent needs to be accessible.
2-Nail plates missing at plumbing throughout.
3-Studs are over-notched at laundry wall.
4-Holes in bedroom are drilled less than 2" from bottom.
5- Install ductwork per manufacurer's instructions.
6-Complete framing.
Nor ready. Inspection stopped. If inspection does not pass next time, a re-inspection fee will be assessed.