Inspection History Details
Inspection Status: Not Applicable
Inspection History: RSBU - Building Progress
Permit Number - TC-RES-0825-03908
Inspection Description - RSBU - Building Progress
Inspection Status - Not Applicable
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/20/2025 | RSBU - Building Progress | Not Applicable | duplicate scheduled in error | |
| 11/20/2025 | RSBU - Building Progress | Re-inspection required | ||
| 11/20/2025 | RSBU - Building Progress | Re-inspection required | 1-Provide proof of UG plumbing approval 2-Provide test of DWV piping. 3-Provide engineering for two beams in ceiling. 4-Move smoke detector in family room to outside of bedroom. 5-Install stud shoes on over-notched/drilled studs per Code. 6-Nail protection at plates at plates need to extend 3” minimum above and below plates. |
|
| 12/11/2025 | RSBU - Building Progress | Partial Pass | Inspection call for residential intermediate, which was added today |