Permit: TC-RES-0824-04679

Parcel: 131071490


Addresses:

6131 E 27TH ST

Inspection Status: Canceled

Inspection History: COT - BULD - SWG Clearance

Date Description Inspector Results Comments
03/19/2026 COT - BULD - SWG Clearance Canceled work incomplete
04/02/2026 COT - BULD - SWG Clearance Passed Southwest Gas Clearance: SWG
04/15/2025 COT - BULD - SWG Clearance Not Ready Appliances not installed; work is at Intermediate stage.
05/05/2025 COT - BULD - SWG Clearance Not Ready work is still at intermediate stage, underground piping is not buried
05/07/2025 COT - BULD - SWG Clearance Re-inspection required 1-Test gauge is incorrect size; it does not show 1/10 of pound increments per Code. 2-Dryer has been eliminated. 3-Tracer wire for underground gas piping is blue; it needs to be yellow. 4- Tankless water heater had not been roughed in per approved plans. 5-Gas piping for rooftop unit terminates in attic with shut-off valve more than three feet from location and inaccessible for rooftop; cannot run flex line through roof sheeting, roof jack, etc. 6-There is no gas piping shown on approved plans; installed 3/4” main seems inadequate for appliances intended size and location. obtain approved revision showing size, type, and location of all tended gas piping.
05/27/2025 COT - BULD - SWG Clearance Not Ready wanted Intermediate but couldn’t schedule it