Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSME - Mechanical Final
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/21/2026 | COT - RSME - Mechanical Final | Re-inspection required | ||
| 09/01/2026 | COT - RSME - Mechanical Final | Not Ready | ||
| 09/03/2026 | COT - RSME - Mechanical Final | Not Ready | ||
| 09/04/2026 | COT - RSME - Mechanical Final | Re-inspection required | 9.4.26 1. Kitchen counter receptacles have to be GFCI protected 2. Water heater T/P line must be CPVC or copper 3. Water is off, please have water on for Final inspections 4. Provide ladder for HVAC inspection 5. Please, have someone at residence or provide updated lockbox code for next inspection. 6. The plumber was at the house when I left and the sliding glass door would not lock |
|
| 09/09/2026 | COT - RSME - Mechanical Final | Re-inspection required | Unable to access property, left voicemail, did not call back | |
| 09/16/2025 | COT - RSME - Mechanical Final | Not Ready | ||
| 09/16/2026 | COT - RSME - Mechanical Final | Not Ready | 9/16/2026 Provide address per previous notes. Receptacle to the right of range shall be GFCI protected. Receptacle at countertop east wall shall be GFCI protected. Provide high water loop at dishwasher. Ensure dishwasher is secured in place. Water heater drip led shall be facing down. Pressure relief valve shall be out of CPVC or copper. Coat exterior plastic pipes on roof. Add flashing to 3” vent line on roof. Provide WR gfci protected receptacle on roof. Mark (X) to the column and row to indicate selected option installed on unit label. Raise gas exhaust per code section r303.5.1. | |
| 09/23/2026 | COT - RSME - Mechanical Final | Passed | 09/23/2026 All corrections made. |