Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
| Date |
Description |
Inspector |
Results |
Comments |
| 05/29/2025 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Re-inspection required |
Install post caps per plan at front porch. Add nails to base plates. Anchor bolts call for every 32" o.c. Add nails to sheathing on west end of dwelling. Provide engineer fix for broken truss rear end. Add bracing at A1M truss. 5/29/2025 |
| 06/04/2025 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Passed |