Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Excavation/Rebar/Zoning
| Date |
Description |
Inspector |
Results |
Comments |
| 11/07/2023 |
COT - RSBU - Excavation/Rebar/Zoning |
|
Re-inspection required |
11/7/23: install test-tee at connection of new soil to existing soil, support entire length of new soil pipe with earth, install a 5 foot stand pipe to test the system, fill the new soil pipe with water to top of 5 foot stack. |
| 11/08/2023 |
COT - RSBU - Excavation/Rebar/Zoning |
|
Not Ready |
11/8/23: not ready for pre-slab. |
| 11/17/2023 |
COT - RSBU - Excavation/Rebar/Zoning |
|
Passed |
|