Inspection History Details
Inspection Status: Partial Pass
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/11/2024 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Partial Pass | 1/11/24: partial for home addition | |
| 02/28/2024 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | 1/11/24: partial for home addition 2/28/24: Post Caps missing at 6x6 post throughout , Simpson ST-18 missing at beam splices, H2.5 clips missing fasteners throughout, plans call for 5 1/18" x 12" beam at screen (revision will be needed for beam installed), anchor bolts must be 32" o.c missing throughout at porch, remove receptacle in porch attic. |
|
| 03/11/2024 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed |