Inspection History: COT - RSBU - Roof Nailing 

Date Description Inspector Results Comments
01/11/2024 COT - RSBU - Roof Nailing  Partial Pass 1/11/24: partial for home addition
02/28/2024 COT - RSBU - Roof Nailing  Re-inspection required 1/11/24: partial for home addition
2/28/24: Post Caps missing at 6x6 post throughout , Simpson ST-18 missing at beam splices, H2.5 clips missing fasteners throughout, plans call for 5 1/18" x 12" beam at screen (revision will be needed for beam installed), anchor bolts must be 32" o.c missing throughout at porch, remove receptacle in porch attic.
03/11/2024 COT - RSBU - Roof Nailing  Passed