Inspection Status: Re-inspection required
Inspection History: COT - RSEL - Electrical Final
Permit Number - TC-RES-0823-07198
Inspection Description - COT - RSEL - Electrical Final
Inspection Status - Re-inspection required
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/22/2024 | COT - RSEL - Electrical Final | Re-inspection required | 7/22/24: label all breakers in main panel. Arc fault protected breakers required for all living spaces in main panel. Cut clean outs to grade. GFCI protected receptacle needed for future dishwasher. | |
| 07/23/2024 | COT - RSEL - Electrical Final | Passed | 7/22/24: label all breakers in main panel. Arc fault protected breakers required for all living spaces in main panel. Cut clean outs to grade. 7/23/24: corrections made. |