Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Partial Pass
Inspection History: COT - RSBU - Excavation/Rebar/Zoning
Permit Number - TC-RES-0823-07045
Inspection Description - COT - RSBU - Excavation/Rebar/Zoning
Inspection Status - Partial Pass
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/14/2024 | COT - RSBU - Excavation/Rebar/Zoning | Partial Pass | Layout only. | |
| 12/19/2025 | COT - RSBU - Excavation/Rebar/Zoning | Re-inspection required | Note: This is a partial inspection for the building only, not the carport or porch. 1-Interior footings are missing. 2-Reinforcing is missing from exterior footings. 3-Hold down devices are missing. 4-Ufer is missing. 5- Plumbing needs wrap. |