Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Parcel: 135072960


Addresses:

7541 E JUAREZ ST


Inspection Status: Not Ready

Inspection History: COT - RSBU - Exterior Clips/Sheathing 

Permit Number - TC-RES-0823-07020

Inspection Description - COT - RSBU - Exterior Clips/Sheathing 

Inspection Status - Not Ready

Date Description Inspector Results Comments
10/25/2023 COT - RSBU - Exterior Clips/Sheathing  Not Ready 1-Install Water-Resistive Barrier behind siding per installation instructions. 2-Siding is not below sill plate plate per installation instructions. 3-Joints both vertical and horizontal are not per installation instructions.

Not Ready; Review installation instructions and install siding per these before rescheduling.
12/14/2023 COT - RSBU - Exterior Clips/Sheathing  Passed 12/14/23: all corrections made