Permit: TC-RES-0726-04209

Parcel: 119032330


Addresses:

527 W 41ST ST

Inspection Status: Re-inspection required

Inspection History: BULD - Electrical Clearance

Date Description Inspector Results Comments
08/07/2026 BULD - Electrical Clearance Re-inspection required 08/07/2026
Secure dead front panel with screw and ensure breakers are flush to dead front. Plug knockout holes at bottom of main service panel. Secure loose flexible metal conduit and breaker box underneath panel. Metal address tag required at front of panel. Please verify riser is properly supported - wood backing looks soft and degraded from weathering. Unable to locate ground rods.
08/17/2026 BULD - Electrical Clearance Passed passed CLEARANCE RECN