Permit: TC-RES-0726-03802

Parcel: 112064210


Addresses:

2402 E COPPER ST

Inspection Status: Partial Pass

Inspection History: COT - RSPL - Rough Soil 

Date Description Inspector Results Comments
08/11/2026 COT - RSPL - Rough Soil  Partial Pass
08/26/2026 COT - RSPL - Rough Soil  Not Ready Not ready. Provide a minimum of 18" of stand pipe at laundry room along with trap. Provide San t at laundry room and ensure there is a minimum of 4" clearance between each trap weir. Ensure laundry pipe is a minimum of 2".
Bathroom underground not approved. Provide a vent through roof for bathroom group. Provide a minimum 2" pipe for shower. Fitting coming from shower is running in the wrong direction. Ensure at next inspection abs is under pressure. 8/26/2026
09/03/2026 COT - RSPL - Rough Soil  Partial Pass
09/11/2026 COT - RSPL - Rough Soil  Passed