Permit: TC-RES-0724-04389

Parcel: 123071480


Addresses:

1225 N WILSON AV

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.

Date Description Inspector Results Comments
07/02/2025 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Re-inspection required 7/2/25
1. Water hammer arrestors needed at washer and refrigerator ice maker.
2. Dryer vent must not be squashed, improper recess vent connection. Provide recess box that allows for a 4" round vent.
3. Provide blocking 36" from floor at wall adjacent to toilet to allow for future grab bars, minimum 42" long.
07/11/2025 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed