Inspection History: COT - RSPL - Gas Pressure Test
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/03/2025 | COT - RSPL - Gas Pressure Test | Re-inspection required | 11.03.2025 Seal top plate penetrations throughout with fire foam, add smoke detector in primary bedroom & hallway, ground metal pancake boxes, brace DWV line midway in water closet and laundry area. Subpanel in utility room cannot be closed off and gas and condensate lines underneath panel will need to be routed above or away from panel - ensure shutoff valve access to gas as well. Refer to E3405.1 of 2018 IRC or 110.26 of NEC 2017 for code details. |
|
| 12/17/2025 | COT - RSPL - Gas Pressure Test | Passed | 12/17/2025 Approved and holding under test. |