Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Roof NailingĀ
| Date |
Description |
Inspector |
Results |
Comments |
| 03/25/2025 |
COT - RSBU - Roof NailingĀ |
|
Re-inspection required |
3/25/25: H3 clips missing throughout per detail 201 and 202, DTC Clip required at 36" o.c at interior non-bearing wall, shot pins at interior non-bearing required 48" o.c and within 4" of sill plate, shear-wall fasteners not per schedule 6" o.c at edge and 12" o.c at field. STOPPED INSPECTION MORE ITEMS MAY BE ADDED. |
| 03/27/2025 |
COT - RSBU - Roof NailingĀ |
|
Passed |
3/27/25 corrections made |