Permit: TC-RES-0724-04277

Parcel: 113080380


Addresses:

817 E ADELAIDE DR

Inspection Status: Passed

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Date Description Inspector Results Comments
03/13/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed
04/11/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required Not ready. Front porch not built per plan. Missing lateral bracing at trusses along with gable end bracing at every 48". Add king stud to SGD. Hallway needs to be 36" at final. Add h25 at bearing trusses. Add cs16 straps to top plates that have been over notched. Bearing truss is not sitting on top plates. Nailing at seal not per schedule. Provide cat walk for unit in attic. 4/11/2025
06/25/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed