Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: TC-RES-0724-04154

Parcel: 123040470


Addresses:

2809 E LESTER ST

Inspection Status: Partial Pass

Inspection History: COT - RSPL - Plumbing Final 

Date Description Inspector Results Comments
07/22/2024 COT - RSPL - Plumbing Final  Partial Pass
07/23/2024 COT - RSPL - Plumbing Final  Passed Please fire foam all top plate, penetrations block, and clamp supply lines to water heater, pipe insulation and sunshield on exterior line on north side of house
7/19/24 please fire foam all penetrations that you can see from the access points, including old pipes and fill the cut pipes as well, the 10 mil tape used to cover the plumbing on the exterior wall is not UV rated and it is already coming loose. Please secure the tape properly not with zip ties and then protect with sunshield that can be paint or anything to keep the tape from rotting.
7/23/24:please insulate exterior lines fully, and sun shield all exterior lines 10 mil tape is not UV Resistant.
7/23/24: corrections made ok to proceed.
07/23/2024 COT - RSPL - Plumbing Final  Re-inspection required No ladder for roof access please caulk exterior penetrations, please insulate exterior lines fully, and sun shield all exterior lines 10 mil tape is not UV Resistant.
7/23/24:please insulate exterior lines fully, and sun shield all exterior lines 10 mil tape is not UV Resistant.