Permit: TC-RES-0724-04066

Parcel: 131111440


Addresses:

5843 E CALLE AURORA

Inspection Status: Re-inspection required

Inspection History: COT - RSPL - Rough Soil 

Date Description Inspector Results Comments
06/01/2026 COT - RSPL - Rough Soil  Re-inspection required 06/01/2026
Add sleeve to ABS pipe going through footing foundation wall, provide 14AWG continuous green tracer wire to pipe outside of slab, water test shower drain pipe and verify wet soil area is leak free using 10ft tall pipe column pressure for DWV system.
06/02/2026 COT - RSPL - Rough Soil  Re-inspection required 6/2/26 see previous notes
06/15/2026 COT - RSPL - Rough Soil  Canceled
06/22/2026 COT - RSPL - Rough Soil  Passed 06/22/2026
Corrections made. Okay to backfill, shading required.