Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: TC-RES-0724-03990

Parcel: 13219059D


Addresses:

4715 S BENTLEY AV

Inspection Status: Re-inspection required

Inspection History: COT - RSEL - Outdoor Lighting

Date Description Inspector Results Comments
02/03/2026 COT - RSEL - Outdoor Lighting Re-inspection required 2-3-26: add arch fault breakers for kitchen, add vacuum breakers at hose bib, cut clean outs to grade, exterior receptacles must be weather resistant gfci's, wrap hose bibs with R3 insulation & at hot side of water heater, missing hammer arrestor at fridge and at dishwasher, install anti tip device at stove, seal water closets, add receptacle covers throughout, install address identification- must be 4" in length and visible from roadway.
02/12/2026 COT - RSEL - Outdoor Lighting Passed 02/12/2026
Corrections made to 2/3/26 inspection and passed on 2/10/26.