Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSEL - Outdoor Lighting
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/03/2026 | COT - RSEL - Outdoor Lighting | Re-inspection required | 2-3-26: add arch fault breakers for kitchen, add vacuum breakers at hose bib, cut clean outs to grade, exterior receptacles must be weather resistant gfci's, wrap hose bibs with R3 insulation & at hot side of water heater, missing hammer arrestor at fridge and at dishwasher, install anti tip device at stove, seal water closets, add receptacle covers throughout, install address identification- must be 4" in length and visible from roadway. | |
| 02/12/2026 | COT - RSEL - Outdoor Lighting | Passed | 02/12/2026 Corrections made to 2/3/26 inspection and passed on 2/10/26. |