Permit: TC-RES-0724-03990

Parcel: 13219059D


Addresses:

4715 S BENTLEY AV

Inspection Status: Re-inspection required

Inspection History: RSBU - Building Final 

Date Description Inspector Results Comments
02/03/2026 RSBU - Building Final  Re-inspection required 2-3-26: add arch fault breakers for kitchen, add vacuum breakers at hose bib, cut clean outs to grade, exterior receptacles must be weather resistant gfci's, wrap hose bibs with R3 insulation & at hot side of water heater, missing hammer arrestor at fridge and at dishwasher, install anti tip device at stove, seal water closets, add receptacle covers throughout, install address identification- must be 4" in length and visible from roadway.
02/10/2026 RSBU - Building Final  Passed 02/10/2026
All correction made to prior 2/3/26 inspection.