Inspection Status: Partial Pass

Inspection History: COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.

Permit Number - TC-RES-0724-03926

Inspection Description - COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.

Inspection Status - Partial Pass

Date Description Inspector Results Comments
05/21/2025 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Partial Pass 5/20/25
1. Conduit for kitchen island needs to be UF rated.
2. All top plate penetrations need to be sealed with fire caulk.
3. Exterior Clips/Sheating inspection needs to be requested.
05/23/2025 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Re-inspection required Pex lines need to be secured every 32” horizontally. Add supports and secure gas lines throughout. At every 6’ for 1/2” & 1” and every 8’ for 1 1/4” & larger. Provide information on securing interior furr out framing to cmu wall. Thermostat at 48”. Fresh air intake has to be 10’ away from vent line. Smoke detector has to be 3’ from bathroom door. Add grommet and ground screw in data box. Screw ground screws to boxes. Add nail plate to electrical line for panel. Add gas bond along with mud ring for access. Flex duct is choked in girder truss area, 1st floor. 5/23/2025
05/27/2025 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed Ok to insulate and sheet rock throughout.