Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Inspection Status: Re-inspection required

Inspection History: RSPL - Plumbing Progress

Date Description Inspector Results Comments
06/13/2024 RSPL - Plumbing Progress Re-inspection required provide 12” depth minimum for kitchen line. missing grey water layout. 6/13/2024
06/21/2024 RSPL - Plumbing Progress Partial Pass plumbing in slab okay to backfill. shading required. pending sewer tie in. 6/21/2024
07/01/2024 RSPL - Plumbing Progress Partial Pass 7/1/24: slab reinforcement passed.
09/05/2024 RSPL - Plumbing Progress Not Ready
11/04/2024 RSPL - Plumbing Progress Re-inspection required DWV not on test. Secure vertical pex lines throughout. Add nail plates to those that are less than an 1 1/4" from face of stud. Exhaust fan not wired in laundry room and missing seals. Missing receptacle for hallway. Add receptacle in master bedroom per wall greater than 2'. Seal off exterior and top penetrations. Provide 18" of copper at water heater and main water line. Missing switches per plan. Stopped inspections other items may occur. 11/4/2024
11/07/2024 RSPL - Plumbing Progress Passed