Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Passed
Inspection History: COT - RSMH - Mobile/Mod Home Final
Permit Number - TC-RES-0625-03213
Inspection Description - COT - RSMH - Mobile/Mod Home Final
Inspection Status - Passed
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/25/2025 | COT - RSMH - Mobile/Mod Home Final | Passed | 11.25.2025 Verified outdoor scope of work at front stair entry to mobile home & new T1-11 siding contained vapor barrier. All work is done in accordance to the 2018 IRC R311.7.5 stair risers & treads, and R312.1.3 guards spaced not more than 4". Risers shall not exceed the 7 3/4" and tread is at least 10". Handrails are within the 34"- 38" limit. Landing width is not less than 36". |