Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/07/2026 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Re-inspection required | 4-7-26: called point of contact at 1133 am but received no answer. I arrived on site at 1136 am and noted that the doors in question were completely open but did not feel comfortable entering the home without the homeowner. I waited until 1150 am before leaving. Please reschedule at your convenience. | |
| 04/08/2026 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Not Ready | needed electrical clearance | |
| 10/13/2026 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Partial Pass | 10/13/2026 Partial pass pending remaining DWV needs to be fixed at bedroom and verify holding under test. Add Boca nail plates to bottom plate conduit at island and bathroom to protect drain within 1.25". Brace air register at bedroom 1. Fire caulk top penetrations at master bedroom behind panel and bathroom vent. Exhaust fan duct needs to be terminated outside at bathroom. |