Inspection Status: Not Ready
Inspection History: RSBU - Building Final
| Date |
Description |
Inspector |
Results |
Comments |
| 07/15/2025 |
RSBU - Building Final |
|
Not Ready |
Indoor unit AC disconnect has a knockout that is open please secure the electrical whip with a half strap or two whole strap on the side of the unit. Please install a P-trap on the condensate and a safety overflow switch. And please sunshield the outdoor line set electrical tape was used. Use a UV protected tape. Open AC outlet behind unit please cover and cap wiring. Please use a Non n flar e fitting cap on the gas supply shut off valve located behind the water heater. |
| 07/21/2025 |
RSBU - Building Final |
|
Not Ready |
|
| 10/23/2025 |
RSBU - Building Final |
|
Passed |
|