Inspection Status: Not Ready
Inspection History: RSBU - Building Final
Permit Number - TC-RES-0625-03054
Inspection Description - RSBU - Building Final
Inspection Status - Not Ready
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/15/2025 | RSBU - Building Final | Not Ready | Indoor unit AC disconnect has a knockout that is open please secure the electrical whip with a half strap or two whole strap on the side of the unit. Please install a P-trap on the condensate and a safety overflow switch. And please sunshield the outdoor line set electrical tape was used. Use a UV protected tape. Open AC outlet behind unit please cover and cap wiring. Please use a Non n flar e fitting cap on the gas supply shut off valve located behind the water heater. | |
| 07/21/2025 | RSBU - Building Final | Not Ready | ||
| 10/23/2025 | RSBU - Building Final | Passed |