Permit: TC-RES-0625-03046

Parcel: 121090490


Addresses:

5307 E LESTER PL

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.

Date Description Inspector Results Comments
01/09/2026 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Re-inspection required No answer at 12:50 PM. After texting at 12:41.
02/27/2026 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed Note: Gas line under slab will be re-routed before final.
12/15/2025 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Re-inspection required 12.15.25
Missing receptacle at bedroom area, receptacle required within 6 feet of door and within every 12 ft after.
Missing receptacle at bathroom vanity.
Add nail plates throughout to protect pex and romex
Add 2 inch Boca/bang plates to protect plumbing as discussed
Interior DWV must be under test
12/23/2025 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Re-inspection required 1-Need stud shoes at laundry wall.
2-Romex entering metal box needs protction.
3-Finish vent piping and provide test for DWV piping.
4-Window is missing in new laundry room.
5-Need operable window in new bathroom.
6-Sill plates in new laundry are not per Code.
7-Beam is notched.
8-Termite damage needs to be mitigated.