Permit: TC-RES-0625-02875

Parcel: 140130810


Addresses:

1930 E WYOMING ST

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Date Description Inspector Results Comments
09/11/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required 9-11-25: add anchor bolts at marked locations, add a shot pin within 6" at the ends of each plate-minimum 2 per plate, seal vapor barrier. Have architect submit a letter for exterior wall-plans call for osb & stucco. Have a licensed contractor submit any letter to the city for review & approval regarding exterior wall siding nailing. The letter must document that nailing along the edges was done per the 2018 IRC. Another option is to remove all exterior 2x4 trim so that we can verify edge nailing.
09/12/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Partial Pass 9.12.2025
Partial pass pending anchor bolts at marked locations during intermediate inspection, okay to proceed. Architectural letters received and being uploaded to the TDC online portal.