Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Permit Number - TC-RES-0624-03791

Inspection Description - COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
06/16/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required Missing Htt4 holdowns per schedule. Loose anchor bolts throughout. Missing nuts and washers and bolts. Two pins required at bottom plate greater than 12" and 6" from edges. Add anchor bolts throughout no more than 12" from edges. Add nails throughout at shear walls being penetrated more than 1/8". Interior shear wall nailing not per schedule. Connection from beam to post not per plan. Missing nails at post cap. Stopped inspection other items may occur. 6/16/2025
07/09/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required Missing Htt4 holdowns per schedule. Loose anchor bolts throughout. Missing nuts and washers and bolts. Two pins required at bottom plate greater than 12" and 6" from edges. Add anchor bolts throughout no more than 12" from edges. Add nails throughout at shear walls being penetrated more than 1/8". Interior shear wall nailing not per schedule. Connection from beam to post not per plan. Missing nails at post cap. Stopped inspection other items may occur. 6/16/2025
7/9/25: Anchor bolt spacing not per plan at marked locations, shot pins required at interior walls at marked locations, exterior shear walls not fastened per schedule, nailing must be 3/8" from edge and penetrate no more than 1/8". HTT4 must be properly secured.
08/05/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed All corrections were made. Approved. 8/5/2025