Inspection History Details
Inspection Status: Not Ready
Inspection History: RSBU - Building Final
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/11/2026 | RSBU - Building Final | Not Ready | ||
| 06/12/2026 | RSBU - Building Final | Re-inspection required | 6.12.26 Unit 1. 1. High loop needed at dishwasher 2. T-stat too high 3. Water heater needs shackle at breaker or Disconnect next to water heater. 4. Loose receptacles throughout 5. Storage unit is still up 6. North Basement windows is still there 7. Need smoke detector in the basement UNIT 2; 1. Master bedroom smoke detector too close to supply register, need 3ft minimum. 2. Missing anti tip on stove 3. Missing 2nd small appliance circuit in kitchen 4. Missing receptacles in living room and hallway 5. Loose receptacles throughout |
|