Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Date Description Inspector Results Comments
10/24/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required 10-24-25: add an anchor bolt to marked locations-a minimum of 2 anchor bolts are required for a plate that is 12" in length. Add nails to exterior sheathing at south wall (add backing for splices and nail sheathing 6" o.c. along splice/edges and 12" o.c. In the field), missing backing at bathroom-see page 1 for details).
10/27/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required 10-27-25: backing at shower, tub, and toilet missing-see page 1 detail's A, B, C, & D for information.
10/29/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed 10.29.2025
Corrections made to backing in bathroom group.