Inspection Status: Re-inspection required
Inspection History: COT - RSPL - Rough Soil
Permit Number - TC-RES-0623-05944
Inspection Description - COT - RSPL - Rough Soil
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/07/2023 | COT - RSPL - Rough Soil | Re-inspection required | Not ready. 2" shower line north of build is creating an S TRAP. The separation of the pipes need to be 2x's the pipe diameter from the edges not center of the pipe. 11/7/2023 | |
11/08/2023 | COT - RSPL - Rough Soil | Re-inspection required | Not ready. 2" shower line north of build is creating an S TRAP. The separation of the pipes need to be 2x's the pipe diameter from the edges not center of the pipe. 11/7/2023 11/8/23: not per plan |
|
11/27/2023 | COT - RSPL - Rough Soil | Partial Pass | 11/27/23: Laundry drain is going to be tied into bathroom group wet venting and this is not allowed per code (IRC P3108.1). as-built required. proceed at risk. | |
11/28/2023 | COT - RSPL - Rough Soil | Passed | Corrections were made. Rebar in footings per plan. Okay for concrete placement. 11/28/2023 |