Inspection History Details
Inspection Status: Not Ready
Inspection History: BULD - Electrical Clearance
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/12/2025 | BULD - Electrical Clearance | Not Ready | not ready no wiring connections to box due to theft | |
| 04/21/2025 | BULD - Electrical Clearance | Re-inspection required | 4-21-25, exposed wiring inside of panel and missing dead plate. | |
| 05/09/2025 | BULD - Electrical Clearance | Failed | FAILED, permit of the electric service panel upgrade and revision to the plan is required to proceed with electrical clearance. New wiring and no service panel was present at time of inspection | |
| BULD - Electrical Clearance | Canceled | CA by contractor | ||
| 06/02/2025 | BULD - Electrical Clearance | Re-inspection required | 4-21-25, exposed wiring inside of panel and missing dead plate. 5/9/25 - FAILED, permit of the electric service panel upgrade and revision to the plan is required to proceed with electrical clearance. New wiring and no service panel was present at time of inspection 6/2/25: revision was submitted and approved but work on site has not been. Completed per plans. Location of new panel is not per approved revision, panel is not ready for clearance. Grounding clamps at ground rods need to be properly secure, dead front must have appropriate cover and service feeders must be installed, please correct all work and install new 200Amp panel. |
|
| 06/02/2025 | BULD - Electrical Clearance | Re-inspection required | 4-21-25, exposed wiring inside of panel and missing dead plate. 5/9/25 - FAILED, permit of the electric service panel upgrade and revision to the plan is required to proceed with electrical clearance. New wiring and no service panel was present at time of inspection 6/2/25: revision was submitted and approved but work on site has not been. Completed per plans. Location of new panel is not per approved revision, panel is not ready for clearance. Grounding clamps at ground rods need to be properly secure, dead front must have appropriate cover and service feeders must be installed, please correct all work and install new 200Amp panel. |
|
| 06/23/2025 | BULD - Electrical Clearance | Passed | 6.23.25 TEP INCR code. New panel installed and corrections made per plan via REV1. Deadfront present, address label present, proper securing, bonding and grounding verified. | |
| 06/23/2025 | BULD - Electrical Clearance | Passed | 6.23.25 TEP INCR code. New panel installed and corrections made per plan via REV1. Deadfront present, address label present, proper securing, bonding and grounding verified. |