Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: TC-RES-0526-02453

Parcel: 117082880


Addresses:

940 S 2ND AV

Inspection Status: Re-inspection required

Inspection History: COT - RSEL - Electrical Underground 

Date Description Inspector Results Comments
06/15/2026 COT - RSEL - Electrical Underground  Re-inspection required O6/15/2026
Neutral and grounding wires are landed on same busbar at subpanel, this is allowed at main service panel only. Refer to 2024 IRC E3607.3.1.
06/16/2026 COT - RSEL - Electrical Underground  Passed 6-16-26: underground electrical approved.