Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/14/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | 1. The riser height shall be not more than 7 3/4 inches (196 mm). The greatest riser height within any flight of stairs shall not exceed the smallest by more than 3/8 inch . 2. Treads need to be minimum of 10 inches. 3. Treads less than 11 inches require nosing projecting between 3/4 inch to 1 1/4 inch max. Also, no greater than 3/8 inches difference between shortest and longest. 4. Handrails are too wide, max for a non circular handrail is 1.5 inches by 1.5 inches. |
|
| 09/05/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | 9.5.2025 Corrections made to 8.14.2025 inspection. |