Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: TC-RES-0525-02617

Parcel: 141141520


Addresses:

9584 E ASHFORD DR

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Date Description Inspector Results Comments
08/14/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required 1. The riser height shall be not more than 7 3/4 inches (196 mm). The greatest riser height within any flight of stairs shall not exceed the smallest by more than 3/8 inch .

2. Treads need to be minimum of 10 inches.

3. Treads less than 11 inches require nosing projecting between 3/4 inch to 1 1/4 inch max. Also, no greater than 3/8 inches difference between shortest and longest.

4. Handrails are too wide, max for a non circular handrail is 1.5 inches by 1.5 inches.
09/05/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed 9.5.2025
Corrections made to 8.14.2025 inspection.