Permit: TC-RES-0525-02559

Parcel: 116271000


Addresses:

116 N CHAMPAGNE PL

Inspection Status: Re-inspection required

Inspection History: RSPL - Plumbing Progress

Date Description Inspector Results Comments
05/22/2025 RSPL - Plumbing Progress Re-inspection required 5/22/25:Water hammer arrestor required at dishwasher at kitchen and washer at laundry room, seal all penetrations through top plates, nail plates required throughout where piping is closer than 1 1/4" to face of 2x, studs are over notched throughout (please verify if studs are bearing or nonbearing and address the issue accordingly, insulation required at hose bib and insulation shall be UV protected.
05/28/2025 RSPL - Plumbing Progress Re-inspection required 5.28.25 All requests completed except over notched stud in bathroom.
06/03/2025 RSPL - Plumbing Progress Passed