Inspection Status: Re-inspection required
Inspection History: RSPL - Plumbing Progress
| Date |
Description |
Inspector |
Results |
Comments |
| 05/22/2025 |
RSPL - Plumbing Progress
|
|
Re-inspection required |
5/22/25:Water hammer arrestor required at dishwasher at kitchen and washer at laundry room, seal all penetrations through top plates, nail plates required throughout where piping is closer than 1 1/4" to face of 2x, studs are over notched throughout (please verify if studs are bearing or nonbearing and address the issue accordingly, insulation required at hose bib and insulation shall be UV protected. |
| 05/28/2025 |
RSPL - Plumbing Progress
|
|
Re-inspection required |
5.28.25 All requests completed except over notched stud in bathroom. |
| 06/03/2025 |
RSPL - Plumbing Progress
|
|
Passed |
|