Permit: TC-RES-0524-02779

Parcel: 137334490


Addresses:

1767 W SAUVIGNON DR

Inspection Status: Re-inspection required

Inspection History: COT - RSPL - Plumbing Final 

Date Description Inspector Results Comments
05/10/2024 COT - RSPL - Plumbing Final  Re-inspection required 5/10/24: seal all penetrations going through top plate (throughout), nail plate missing under kitchen cabinets, properly support feed to water closet in hallway, 18" of copper required before transitioning over to pex at water heater, pex lines above thermal envelope must be insulated, new water main was ran from meter to home without previous inspection (please open up a 2' section at two locations to ensure proper depth and presence of tracer wire).
05/14/2024 COT - RSPL - Plumbing Final  Passed 5/10/24: seal all penetrations going through top plate (throughout), nail plate missing under kitchen cabinets, properly support feed to water closet in hallway, 18" of copper required before transitioning over to pex at water heater, pex lines above thermal envelope must be insulated, new water main was ran from meter to home without previous inspection (please open up a 2' section at two locations to ensure proper depth and presence of tracer wire).
5/14/24: corrections made ok to continue.