Permit: TC-RES-0524-02778

Parcel: 138111880


Addresses:

6113 S DUNTON AV

Inspection Status: Re-inspection required

Inspection History: RSPL - Plumbing Progress

Date Description Inspector Results Comments
03/05/2025 RSPL - Plumbing Progress Re-inspection required 3-5-25, water heater not connected to code standards. Missing PTR line-run ptr line to the exterior and install between 6” to 24 “ from grade, catch pan required, pvc directly connected to water heater is not allowed, B-vent requires a 1inch clearance. Also, noted were pex lines within 12 inches of can lights ( block or insulate pex lines within/in 12 “) add straps to DWV, remove all pex,electrical, and flex from grid, add firefoam to any penetrations at top plates.

Mechanical/electrical: provide a set of approved plans to include new ductwork, HVAC. Missing 50 amp breaker for HVAC together with disconnect. Electrical: a receptacle is required within 6 ft. of a door and additional receptacles no greater than 12 feet apart. Add receptacles to master bedroom, hallway, and any walls greater than 2 feet, smoke detectors are required in each bedroom and adjacent room thereafter. (hardwire all smoke detectors), arch fault breakers are required-see code requirements, secure all electrical wires with a staple no greater than 12 inches from receptacle/light switches.
06/14/2024 RSPL - Plumbing Progress Re-inspection required New gas line from meter to house ok to backfill.
Branch to water heater ok.
Branch to island stove must be redone with proper sealed vent chase to the exterior.
08/21/2024 RSPL - Plumbing Progress Not Ready
08/27/2024 RSPL - Plumbing Progress Not Ready Failed - detailed revised plans are required for the remodel work being performed, please provide approved plans on site for inspection
09/10/2024 RSPL - Plumbing Progress Partial Pass 9/10/24: Gas pressure test passed. ok to backfill. shading required. gas piping per plans.
11/25/2025 RSPL - Plumbing Progress Re-inspection required No access