Permit: TC-RES-0523-05267

Parcel: 125050820


Addresses:

2409 E 5TH ST

Inspection Status: Passed

Inspection History: RSME - Mechanical Progress 

Date Description Inspector Results Comments
05/03/2024 RSME - Mechanical Progress  Passed
12/06/2023 RSME - Mechanical Progress  Re-inspection required Not ready. Missing ground screws at all metal boxes. Add nail plates to lines that are less than an 1" 1/4. Add fire blocking to the raised ceilings. Fire foam all top penetrations and open cavities. Secure any loose electrical lines. Electrical line that is in the block wall needs to be in conduit or approved material for any moisture. Missing receptacle at kitchen counter top. HVAC work is not completed. Add blocking at home runs and secure lines. 12/6/2023