Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Parcel: 125050820


Addresses:

2409 E 5TH ST


Inspection Status: Passed

Inspection History: RSEL - Electrical Progress

Permit Number - TC-RES-0523-05267

Inspection Description - RSEL - Electrical Progress

Inspection Status - Passed

Date Description Inspector Results Comments
05/03/2024 RSEL - Electrical Progress Passed
12/06/2023 RSEL - Electrical Progress Re-inspection required Not ready. Missing ground screws at all metal boxes. Add nail plates to lines that are less than an 1" 1/4. Add fire blocking to the raised ceilings. Fire foam all top penetrations and open cavities. Secure any loose electrical lines. Electrical line that is in the block wall needs to be in conduit or approved material for any moisture. Missing receptacle at kitchen counter top. HVAC work is not completed. Add blocking at home runs and secure lines. 12/6/2023