Permit: TC-RES-0523-05181

Parcel: 126191170


Addresses:

815 S CATALINA AV

Inspection Status: Re-inspection required

Inspection History: RSBU - Building Final 

Date Description Inspector Results Comments
RSBU - Building Final  Re-inspection required 6/26/24: missing address plaque. Clean outs need to be cut to grade. Paint vent pvc on roof. Laundry receptacle not GFCI protected. Arc fault protected breakers needed for all living spaces in main panel. Paint pvc clean out for laundry room exterior. Missing interconnected smoke detectors throughout house in bedrooms and outside of sleeping quarters.
06/27/2024 RSBU - Building Final  Passed