Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Parcel: 117084380


Addresses:

815 S 4TH AV


Inspection Status: Re-inspection required

Inspection History: COT - RSPL - Plumbing Final 

Permit Number - TC-RES-0523-05156

Inspection Description - COT - RSPL - Plumbing Final 

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
06/18/2025 COT - RSPL - Plumbing Final  Re-inspection required 6-18-25: all exterior receptacles must be weather resistant, missing smoke detector in hallway, missing hammer arrestors at laundry room and at dishwasher, 3" clearance from grade required at condenser, paint all exterior plastic, install a clamp for a/c condenser whip, missing address identification on house, wrap copper with insulation and 10 mil tape.arch fault breakers required for kitchens, hallways, bedrooms, laundry and living room.
06/23/2025 COT - RSPL - Plumbing Final  Passed