Inspection Status: Re-inspection required
Inspection History: RSBU - Building Final
| Date |
Description |
Inspector |
Results |
Comments |
|
RSBU - Building Final |
|
Re-inspection required |
6-18-25: all exterior receptacles must be weather resistant, missing smoke detector in hallway, missing hammer arrestors at laundry room and at dishwasher, 3" clearance from grade required at condenser, paint all exterior plastic, install a clamp for a/c condenser whip, missing address identification on house, wrap copper with insulation and 10 mil tape.arch fault breakers required for kitchens, hallways, bedrooms, laundry and living room. |
| 06/23/2025 |
RSBU - Building Final |
|
Passed |
|