Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: TC-RES-0523-04900

Parcel: 12212072D


Addresses:

4407 E BELLEVUE ST

Inspection Status: Canceled

Inspection History: RSBU - Building Final 

Date Description Inspector Results Comments
09/29/2023 RSBU - Building Final  Canceled
10/03/2023 RSBU - Building Final  Re-inspection required 10/3/23: verify max number of wires in attic junction box (missing cover), circuit 9 (master bedroom) is tied into circuit 5 kitchen lights and refrigerator, circuit 10 (bedroom #2 is tied into circuit 9 hall light and circuit 3 at kitchen counter. Water hammer arrestor missing at refrigerator, laundry and dishwasher. Whip at water heater not secure on coupling. A/C unit needs p-trap at condensate line and needs to be supported on treated lumber. Panel schedule needs to be reviewed and replaced circuits are missing and tied together.
RSBU - Building Final  Passed